Quick Installation Guide 3. Configuring the MediaPack
Version 5.0 23 September 2007
3.3.2.3 Defining Voice Coders
The gateway communicates with Mediation Server using either the G.711 A-law or G.711
µ-law coder. You can change the default coder using the gateway's Embedded Web Server.
¾ To define the coder, take these 3 steps:
1. Open the ‘Coders' screen (Protocol Management menu > Protocol Definition > Coders).
Figure 3-11: Coders Screen
2. From the 'Coder Name' drop-down list, select the required coder.
3. Reset the gateway by clicking the Maintenance button on the main menu bar. Select the
'BURN' option to burn the configuration to flash memory, and then click the Reset button.
3.3.2.4 Translating Numbers From / To E.164 Using Manipulation Tables for
PBX/PSTN Connectivity
The Embedded Web Server's Manipulation tables provide the ability to translate (normalize)
numbers dialed in standard E.164 format to various formats and vice versa. Manipulation is
necessary for your dial plan as Office Communications Server 2007 uses the standard E.164
format while your PBX or PSTN implements other number formats for dialing.
Due to Office Communications Server 2007normalization rules, the gateway may need to perform
number manipulation for outbound calls (i.e., calls received from OCS client via Office
Communications Server 2007) and inbound calls (i.e., calls destined for OCS client). If the
gateway is connected to a PBX or directly to the PSTN, the gateway may need to perform
number manipulations for the called and/or calling number to match the PBX or PSTN interfaces
dialing rules or to match Office Communications Server 2007 E.164 format.
Manipulation number configuration examples are provided for inbound and outbound calls in
Section 3.3.2.4.2 on page 26.