Allied International AT-8724XL Switch User Manual


 
4 AT-8700XL Series Switch
C613-04042-01 REV D
Selecting a Site
The switch can be installed in a standard 19-inch rack or on a level surface such
as a desktop or bench. When installing the switch, choose a site that:
Allows adequate airflow around the switch and its vents.
Is free of dust and moisture.
Will maintain an ambient temperature range of 0 to 40º C (32 to 104º F) and
a humidity range of 5 to 95% non-condensing.
Has a reliable and earthed (grounded) power supply circuit, preferably
dedicated and filtered.
Does not expose cabling to sources of electrical noise, such as radio
transmitters, broadband amplifiers, power lines, electric motors, and
fluorescent fixtures.
Allows easy access to the switch’s power and cable connections.
Will allow all related network devices to be connected to the switch
without exceeding maximum cable length limitations. See the AT-8700XL
Series Hardware Reference for cable length specifications.
Installing the Switch
All AC and DC versions of this equipment must be earthed.
Follow these steps to install the switch:
1. Before installing the switch, read the safety information
For safety information, see the Safety and Statutory Information booklet. A
copy of this booklet is supplied with each switch, and can also be found on
the Documentation and Tools CD-ROM or at
www.alliedtelesyn.co.nz/support/at8700xl/
2. Gather the tools and equipment you will need
If installing a DC version of the switch, you will need a DC power source,
DC supply cable, and wire strippers (see step 9).
If the switch is to be connected to a redundant power supply, you will need
a redundant power supply unit and cable (see step 11).
3. Choose a suitable site for the switch
Either a flat surface or 19 inch rack.
4. Unpack the switch
Verify the package contents. If any items are damaged or missing, contact
your sales representative.