Allied Telesis AT-SBX3161 Switch User Manual


 
SwitchBlade x3112 Installation Guide
87
Starting a Local Management Session
The procedure in this section explains how to start a local (out-of-band)
management session using the RJ-45 terminal port on the
AT-SBx31CFC
Management Fabric Card. You can use a local management session to
configure the switch’s operating parameters and view performance and
error statistics.
To start a local management session, perform the following procedure:
1. Connect the RJ-45 end of to the Console RS-232 Port on the front
panel of the
AT-SBx31CFC Fabric Control Card, as displayed in
Figure 58.
Figure 58. Connecting the Management Cable to the Console RS-232 Port
Note
The management cable included with the AT-SBx31CFC Fabric
Control Card.
Connect the other end of the cable to an RS-232 port on a terminal or a
personal computer with a terminal emulation program.
2. Configure the terminal or terminal emulation program as follows:
Baud rate: Default is 115,000 bps (Range is 9600 to 115200 bps)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
2
4
6
8
10