Allied Telesis AT-SBX3161 Switch User Manual


 
Chapter 3: Troubleshooting
90
PSU Fault LED Flashing Amber on AT-SBx31CFC Fabric Control
Card
Check the PSU System Status LED on the front of the AT-SBx31CFC card
for a solid green or flashing amber status. A flashing amber status LED
indicates a FAULT condition on one or more power supplies.
Check each Fault LED on each AT-SBx3161 System Power Supply and
AT-SBx3165 PoE Power Supply to see which one(s) is solid amber and
then do the following:
You can obtain the current status for each power supply by using the
Switchblade x3112 Management Software by entering the following
commands:
officer SEC>> SHOW PSU
officer SEC>> SHOW PSU FULL
Contact Allied Telesis Technical Support for further assistance. Please
report the power supply fault condition and the information obtained
from the SHOW PSU and SHOW PSU FULL commands.
If the affected power supply needs to be replaced, remove it and install
a replacement power supply. Refer to “Installing the AT-SBx3161
System Power Supply” on page 61.
Note
The AT-SBx3161 System Power Supply and AT-SBx3165 PoE
Power Supply are hot swappable when used in a redunant
configuration. This allows the SwitchBlade x3112 to continue to
operate while you exchange power supplies.