5. [HPOSnCi] - Set Value
This command sets the Horizontal Position to
an absolute value. It also makes the Horizontal
Position adjustment the active control.
Command Format: [HPOSnCiUy]
n = a value from 0 to 20
Ci = card ID (i = slot number)
Uy = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)
Example:
There is an MT106-100 in slot 7 of unit ID 4.
Set the Horizontal Position to the maximum
value of 20 by sending the command
[HPOS20C7U4].
6. [HPOSCi] - Status/Adjust
This command selects the Horizontal Position
adjustment and makes it the active control. It is
also used to return the status of the current
Horizontal Position. As the active control, it
may be adjusted using the [ + ] and [ - ]
commands.
Command Format: [HPOSCiUy]
Ci = card ID (i = slot number)
Uy = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)
Example:
There is an MT106-100 in slot 4 of unit ID 1.
View the current Horizontal Position and make
Horizontal Position the active control.
[HPOSC4U1] 10
[HPOSC4U1] = STATUS command
10 = Feedback of current value
[ + ] & [ - ] = Adjust as required
7. [VPOSnCi] - Set Value
This command sets the Vertical Position to an
absolute value and makes the Vertical Position
adjustment the active control.
Command Format: [VPOSnCiUy]
n = a value from 0 to 20
Ci = card ID (i = slot number)
Uy = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)
Example:
There is an MT106-100 in slot 2 of unit ID 3.
Set the Vertical Position to the value of 12 by
sending the command [VPOS12C2U3].
8. [VPOSCi] - Status/Adjust
This command selects the Vertical Position
adjustment and makes it the active control. It
also returns the status of the current Vertical
Position. As the active control, it may be
adjusted using the [ + ] and [ - ] commands.
Command Format: [VPOSCiUy]
Ci = card ID (i = slot number)
Uy = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)
Example:
There is an MT106-100 in slot 2 of unit ID 3.
View the current Vertical Position and make
Vertical Position the active control.
[VPOSC2U3] 10
[VPOSC2U3] = STATUS/Current value
10 = Feedback of current value
[ + ] & [ - ] = Adjust as required
9. [HSIZEnCi] - Set Value
This command sets the Horizontal Size to an
absolute value and makes the Horizontal Size
adjustment the active control.
Command Format: [HSIZEnCiUy]
n = a value from 0 to 20
Ci = card ID (i = slot number)
Uy = unit id (i = 0 to 9) (refer to the MT100-100