MULTITASKER
400-0394-007
8
Example: [VERC3U2]
VER = Function
C3 = Card ID or Group ID
U2 = Unit ID (optional for Unit ID 0)
For Function, see a detailed explanation under
each command description.
The card ID is a unique identifier. It is equal to
the enclosure slot number, or it may be an
assigned value. As the slot number, the value
can range from 1-4 up to 1-to-20 depending on
the enclosure. If the value is assigned, the ID
may be a maximum of 99. Card ID 0 (C0) is
used for the controller and cannot be
reassigned.
The group ID is a number representing a group
of cards defined with the [WR] command. When
using the group ID, all cards in the group will
perform the given instruction.
NOTE: In this manual, cards will be referenced
by their ID (C1, C2...C99). Typically, the ID
number will be equivalent to the slot number.
Groups will be referenced by their ID (G1-G8).
Changing the position of a card will significantly
affect the commands recorded on software
definitions or third-party control systems.
The unit ID has a value from 0 to 9. Unit ID 0
should be used for single unit operation. If the
unit ID is set to zero, each command may be
used without Ui. Use the command [SETU0], as
explained in the MT100-100 User’s Guide.
Example:
[VERC3]: For Unit ID Zero
[VERC3Ui]: For Unit ID other than Zero
[VERC3]: Equivalent to [VERC3U0]
BASIC COMMANDS
1. [C]
This command displays the status of the card.
Command Format: [Cn]
Cn = Card ID (n = # from 1 to max slots)
Example:
There is an MT106-103 card in slot 4. Sending
the command [C4] to the MultiTasker will yield
feedback similar to the following:
Input: Composite Video
Output Resolution: 1024x768
Brightness: 24
Contrast: 40
Color: 24
Sharpness: 10
Hue: 0
3D Filter OFF
NR ON
Aspect Ratio 4:3
Freeze OFF
If there is no card in slot 4, sending the [C4]
command will not return any feedback.
2. [CnS]
This command saves the card settings. This
configuration will be restored after the system is
reset or powered-up.
Command Format: [CnS]
Cn = Card ID (n = # from 1 to max slots)
S = Save configuration
Example:
The MT106-103 has been set to a resolution of
1024x768 with Composite Video as the active
input. Send [C4S] and receive feedback similar
to the following: