Altinex MT110-103 Switch User Manual


 
MULTITASKER
400-0197-006
14
17. [IO]
This command connects a single input to a
single output in the current matrix configuration.
Command Format: [ImOxCn]
m = Input (m= # from 1 to 8)
x = Output (x = # from 1 to 8)
Cn = Card ID (n = slot # from 1 to max slots)
Example:
Connect Input 1 to Output 1 for the MT110-103
in slot 4. Send the command [I1O1C4] and
Input 1 will be connected to Output 1.
18. [IO*]
This command connects a single input to all the
outputs in the current matrix configuration.
Command Format: [ImO*Cn]
m = Input (m = # from 1 to 8)
Cn = Card ID (n = slot # from 1 to max slots)
Example:
Connect Input 1 to all outputs for the MT110-103
in slot 4. Send the command [I1O*C4] and
Input 1 will be connected to all outputs.
19. […P] PATH
This command will set the path for the output,
but it is not active until the switch command,
[SW], is executed. Commands ending in ‘P’ are
not executed immediately. The path for outputs
on multiple cards or the same card can be
preloaded. See the examples for the [ON] and
[OFF] commands.
20. [SW] – SWITCH
This command immediately connects inputs and
outputs previously set with the PATH command.
The command switches all paths set on this
card and all other cards in the enclosure. See
the examples for the [ON] and [OFF]
commands.
21. [OSI]
This command sets the input offset value that is
applied to all inputs. The default is zero, or
Input 1 equals Input 1.
Command Format: [OSImCi]
m = Offset (m = # from 0 to 128)
Ci = Card ID (i = # from 1 to max slots)
Example:
[OSI16C4] sets the input offset to 16 for C4. The
inputs on C4 will now be their physical number
plus the offset value. In this case, Input 1 would
now be Input 17.
22. [OSO]
This command sets the output offset value that
is applied to all outputs. The default is zero, or
Output 1 equals Output 1.
Command Format: [OSOmCi]
m = Offset (m = # from 0 to 128)
Ci = Card ID (i = # from 1 to max slots)
Example:
[OSO16C4] sets the output offset to 16 for the
C4. The outputs on C4 will now be addressed by
the value of their physical number plus the offset
value. In this case, Output 1 would now be
Output 17.
23. [VLO]
This command sets the absolute volume level
for a given output.
Command Format: [VLOmAvCn]
m = Output (m = # from 1 to 8)
v = Volume Level (v = # from 1 to 32)
Cn = Card ID (n = # from 1 to max slots)
Example:
There is an MT110-103 card in slot 4. Set the
output volume of Output 2 to 16 by sending the
command [VLO2A16C4].