American Dynamics KT-400 Network Card User Manual


 
DN1726-0811
6
Inputs
There are 16 onboard inputs on the KT-400 Ethernet Four-Door Controller. Up to 240 more can be added through the
addition of expansion modules, such as the KT-MOD-INP16, for a total of 256 inputs. Each input can be individually
configured for one of the following application:
Door contact (4 onboard)
T.Rex (Request to Exit Detector) (4 onboard)
Interlock (4 onboard)
Floor Selection for Elevator Application
•Elevator Action
External Alarm System Status (Armed / Disarmed)
External Alarm System Alarm (Alarm / Secure)
External Alarm System Zones
Relays to trigger on each input in alarm event
Zone shunt: Single or group of zones can be permanently or temporarily 'shunted' to a secure state on the same
controller. Shunt method includes:
- Zone Shunt by another Zone - When a zone in alarm is programmed to shunt another zone / group of zones.
- Zone Shunt on Unlock - When a zone is temporarily frozen to its actual state (alarm or secured) after an access
granted.
- Manual Shunt - Operator can manually 'Shunt' a zone to a secure state.
- Disarmed Door Shunt - When alarm system is disarmed, some zones may be 'Shunted' to a secure state.
- Entry / Exit Delay Shunt - When a user is in the process of disarming / arming the alarm system and entry / exit
delay prevails, some zones may be 'Shunted' to a secure state.
Arming / Disarming Request
Postpone Arming Request
Tamper switch input: The tamper switch is a non-programmable 'Fixed-Function' input. It is used to identify tampering of
the KT-400 cabinet.
Lock Outputs
There are 4 onboard lock outputs and they are supervised. The locking function can also be performed by any onboard
relay configured for this functionality.
Relay Outputs
There are 4 onboard relay outputs. Up to 256 relay outputs can be supported through the addition of expansion modules
such as the KT-MOD-REL8.
Reader Outputs
There are 4 different possible outputs for each of the 4 onboard reader interfaces for a total of 16 programmable outputs.
Reader outputs are used to give user visual and/or audible feedback on the ongoing access events.
Reader Interfaces
There are 4 onboard reader interfaces. They can be programmed for Wiegand or ABA (Clock and Data) readers.
Elevator Interface
The KT-400 Ethernet Four-Door Controller supports elevator interfacing with the addition of expansion modules such as
the KT-MOD-REL8, KT-MOD-INP16 and KT-MOD-OUT16.
Alarm Panel Interface
The KT-400 Ethernet Four-Door Controller supports alarm panel interfacing with the appropriate connections made
between zone inputs, relay outputs and the alarm system panel.
Automatic Port Detection
The KT-400 Ethernet Four-Door Controller automatically detects the site communication speed set by EntraPass as well
as the communication port which can be IP (ETHERNET #1), RS-485 (COM1) or RS-232 (COM3).