AVE VSSI-PRO Network Card User Manual


 
27
Figure 31: BISYNC Sub-Menu
ADDRESS SET UP ANY
DATA ENCODE NRZ
DATA CODING ASCII
EXIT
ADDRESS SETUP ANY
DATA ENCODE NRZ
DATA CODING ASCII
BAUD RATE 2400
EXIT
Figure 32: SDLC Sub-Menu
PROGRAMMING THE VSSI-PRO
VSSI-Pro VIDEO SERIAL ATM INTERFACE
ADDRESS SETUP
Choices : ANY, 1 through 254
Press the “Up” or “Down” button to move the cursor to “ADDRESS SETUP” and press “Set”. The cursor will start
flashing. Press the “Up” or “Down” button to toggle between values and press “Set” when the desired value is dis-
played.
DATA ENCODE
Choices : NRZ, NRZI, NRZID
Press the “Up” or “Down” button to move the cursor to “DATA ENCODE” and press “Set”. The cursor will start flash-
ing. Press the “Up” or “Down” button to toggle between values and press “Set” when the desired value is displayed.
DATA CODING
Choices : ASCII or EBCDIC
Press the “Up” or “Down” button to move the cursor to “DATA ENCODE” and press “Set”. The cursor will start flash-
ing. Press the “Up” or “Down” button to toggle between values and press “Set” when the desired value is displayed.
SDLC
Press the “Up” or “Down” button to move the cursor to “SDLC” and press “Set”. The following sub-menu will appear:
DATA BITS
Choices : 7 or 8
Press the “Up” or “Down” button to move the cursor to “DATA BITS” and press “Set”. The cursor will start flashing.
Press the “Up” or “Down” button to toggle between values and press “Set” when the desired value is displayed.
In addition to each item in this sub-menu and in the sub-menus for BISYNC and SDLC will be the settings for these
formats, one of which you chose in the ATM SELECT sub-menu. The address settings are ASYNC or 0 through 254.
BAUD RATE choices are from 1200 to 115200. PARITY choices are NONE, EVEN, and ODD. DATA BITS can be 7 or 8.
Do not change these settings except for specific applications or for troubleshooting purposes.
BISYNC
Press the “Up” or “Down” button to move the cursor to “BISYNC” and press “Set”. The following sub-menu will appear: