AMT Datasouth 4600 All in One Printer User Manual


 
7
Notes:
1. You should perform a media calibration after installation and when
changing to a different type or size of media.
2. Before calibration, you must load the media and ribbon properly and move
the label sensor to the correct position avoiding holes.
3. After calibration the printer saves parameters to FLASH. Without correct
calibration gap detection is easily lost during printing especially for small
labels (less than 1.5 inches in height).
4. After self-test, the printer is in dump mode. For normal operation, you must
press CANCEL to restart the printer.
LCD Display
The FM 4600 PLUS Series models have a LCD that shows:
printer status
printer settings
input data from a keyboard or barcode reader
The first parameter is either 203 or 300, which stands for the print resolution. The
second parameter indicates the emulation (printer language), PAL/PPLZ, PPLA,
or PPLB.
After power-on, the LCD displays the following message as examples:
FM 4602 PLUS Series
FM 4603 PLUS Series
If a keyboard is plugged in, the display shows:
FM 4602 PLUS Series
(203, PAL/PPLZ)
(300, PAL/PPLZ)
(203, PAL/PPLZ)
<ESC> FOR KEYBD