AMX AVS-SL-PR-0401-0601 Switch User Manual


 
SET Commands
8
AVS-SL-PR-0401-0601
Attenuation (Changes Level on selected Input only)
The Volume level increases 0.5db each time the following command is sent:
The Volume level decreases 0.5db each time the following command is sent:
Absolute Attenuation Level
An attenuation value can be set directly using the following command:
with 00 as (0dB)
Mute ON
Mute OFF
Front Panel Disable
Front Panel Enable
Memory Reset (sets 2011 to Default Factory Settings)
Change Address (Sets 2011 to New Address)
Byte 1 Byte 2 Byte 3
(Header) (Address) (Increase)
E8 00 to FF 0D
Byte 1 Byte 2 Byte 3
(Header) (Address) (Decrease)
E8 00 to FF 0E
Byte 1 Byte 2 Byte 3 Byte 4
(Header) (Address) (Volume Value)
E8 00 to FF 0F 00 to 1F
Byte 1 Byte 2 Byte 3
(Header) (Address)
E8 00 to FF 0B
Byte 1 Byte 2 Byte 3
(Header) (Address)
E8 00 to FF 0C
Byte 1 Byte 2 Byte 3
(Header) (Address)
E8 00 to FF 40
Byte 1 Byte 2 Byte 3
(Header) (Address)
E8 00 to FF 41
Byte 1 Byte 2 Byte 3
38 62 DC
Byte 1 Byte 2 Byte 3 Byte 4
(Address number)
38 62 D9 00 - FF