AMX TPI-PRO-2 Network Router User Manual


 
Overview
5
TPI-PRO Total Presentation Interface - Pro Edition
TPI-PRO Specifications (Cont.)
Serial Touch Drivers: For an updated list of available serial touch input drivers that are selectable by
using the TOUCH button on the front panel of the TPI-PRO, visit
www.amx.com. Refer to the
List of Available Pixel Display and Refresh
Rates section on page 140 for a more detailed list of Touch Monitors that have
been tested with the TPI-Pro.
USB Drivers: USB Touch drivers are automatically loaded when the USB Touch Monitor is
detected. Refer to www.amx.com for latest list of supported USB touch
drivers.
Button Assignments: Button assignments can be modified in TPD4 (not on the TPI-PROs.)
Button channel range: 1 - 4000 button push and feedback (per address port)
Button variable text range: 1 - 4000 (per address port)
Button states range: 1 - 256 (General Button; 1 = Off State, 2 = On State)
Level range: 1 - 600 (Default level value 0-255, can be set up to 1-65535)
Address port range: 1 - 100
Communication/
Programming:
Master communication and programming is available via an Ethernet
connection. Refer to the
Step 3: Configuring the Ethernet Connection
Type section on page 34 for more information.
There are several methods of TPI-PRO communication and programming
available:
DHCP - Refer to the IP Settings section - Configuring a DHCP Address over
Ethernet section on page 33 for more information.
Static IP - Refer to the IP Settings section - Configuring a Static IP Address
over Ethernet section on page 33 for more information.
URL - Refer to the Master Connection section - NetLinx Master Ethernet IP
Address - URL Mode section on page 35 for more information.
Listen - Refer to the Master Connection section - NetLinx Master Ethernet IP
Address - Listen Mode section on page 36 for more information.
Auto - Refer to the Master Connection section - NetLinx Master Ethernet IP
Address - Auto Mode section on page 37 for more information.
NPD (UPD - Refer to the Master Connection section - NetLinx Master
Ethernet IP Address - NDP (UDP) Mode section on page 37 for more
information.
URL (UPD) - Refer to the Master Connection section - NetLinx Master
Ethernet IP Address - URL (UDP) Mode section on page 38 for more
information.
Enclosure: Metal with black matte finish
Operating/Storage
Environment:
• Operating Temperature: 0° C (32° F) to 40° C (104° F)
• Operating Humidity: 5% to 85% RH Non-Condensing
• Storage Temperature: -10° C (14° F) to 70° C (158° F)
• Storage Humidity: 0% to 85% RH Non-Condensing
Dimensions (HWD): 2.24" x 17.00" x 10.27"
5.69 cm x 43.18 cm x 26.09 cm
Weight: 8.25 lbs (3.74 kg)
Certifications: FCC (Class B)
•CE
IEC60950
Included Accessories: 2-pin PWR connector (41-5025)
Assembly Kit (Four-#10-32 screws and Four-#10 washers) (KA0001)
Rack Ear brackets for shelf, wall, and under-table mounting (60-0900-03)
TPI-PRO Quick Start Guide (93-2275-101)
NXA-USBTN, TakeNote USB Computer Control Stick (FG070-603)