Andis Company P333T-PWR Switch User Manual


 
Prepare for Configuration
22 Quick Start for Hardware Installation: P333T-PWR Stackable Switch
9600 baud
8 bits
1 stop bit
no parity.
-
If you reset or powered up the switch after connecting and configuring the terminal,
Welcome to P333T-PWR appears followed by the Login Name prompt.
-
If the login prompt does not appear, press a key on the terminal.
3. Enter the default login: root.
-
The Password prompt appears
4. Enter the user level password: root.
-
You can now establish a connection to the Router or the Master switch (indicated
when the SYS front panel LED is ON) using the Session commands and begin the
configuration of module, stack, or router parameters.
Assigning a Stack IP Address
Note:
Note: All P333T-PWR switches are shipped with the same default IP address. You must
change the IP address of the master switch in a stack in order to guarantee that
the stack has its own unique IP address in the network.
The network management station or a workstation running a Telnet client can establish
communications with the stack once this address had been assigned and the stack has been
inserted into the network. Use the CLI to assign the stack an IP address and net mask.
To assign an IP stack address:
1. Establish a serial connection by connecting a terminal to the master switch of the stack.
2. When prompted for a Login Name, enter the default name root
3. When you are prompted for a password, enter the password root. You are now in
Supervisor Level.
4. At the prompt, type:
set interface inband <vlan> <ip_address> <netmask>
Replace <vlan>, <ip_address> and <netmask> with the VLAN,
IP address, and net mask of the stack.
5. Press Enter to save the IP address and net mask.
6. At the prompt, type reset. Type y and press Enter to reset the stack. After the Reset, log
in again as described above.