Argox OS-214 plus Printer User Manual


 
54
LED Indicators: Power and Ready LEDs blink alternately
Power LED Ready LED
ON OFF
OFF ON
Possible Problems Solutions Remarks
Ribbon out Supply the ribbon roll
Ribbon jam Recover the jam
Ribbon sensor error Replace ribbon sensor
Not applicable to
direct thermal
type.
LED Indicators: Only the Power LED blinks
Power LED Ready LED
ON ON
OFF ON
Possible Problems Solutions Remarks
Serial IO error Check the baud rate Not for Centronics
Memory full Add the extension RAM
Cutter failed, or jam
at cutter
Check the cutter
Recover the jam
Occurs only when
installing or setting the
cutter
Hardware error Call for service
55
Miscellaneous
If the host shows "Printer Time out"
1. Check if the communication cable (parallel or serial) is
connected securely to your parallel or serial port on the
PC and to the connector on the printer at the other end.
2. Check if the printer power is turned on.
If the power cord is connected, the power switch is at position "I"
and the power LED is still not illuminated, check the fuse inside
the power adapter case.
If the data has been sent, but there is no output from the printer.
Check the active printer driver, and see if Label Dr. for your
Windows system and the label printer has been selected.
Vertical streaks in the printout usually indicate a dirty or faulty
print head. (Refer to the following examples.)