1.2 System Defaults
The system defaults are the configuration parameters set in the factory. Use command ‘Clear config’ to restore the
defaults.
The following table lists some of the basic system defaults.
Function Parameter Default
Console Port Connection Baud Rate
Data bits
Stop bits
Parity
Local Console Timeout
Auto
8
1
none
300 seconds
Authentication login
Enable Privileged Exec from Normal Exec
Level
RADIUS Authentication
TACACS Authentication
802.1x Port Authentication
HTTPS
Port Security
IP Filtering
Username “admin”
Password “Asante”
Username “admin”
Password “Asante”
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Web Management HTTP Server
HTTP Port Number
HTTP Secure Server
HTTP Secure Port Number
Enabled
80
Disabled
443
SNMP Community Strings
Traps
“public” (read only)
“private” (read/write)
Authentication traps: enabled
Link-up-down events:
enabled
Port Configuration Admin Status
Auto-negotiation
Enabled
Enabled
8 Asante IntraCore IC3624/48 User’s Manual