Asus AP200 Personal Computer User Manual


 
25
IV. Hardware Setup
AP200 Hardware Reference Guide
IV. HW Setup
Air Circulation System
External SCSI Terminator
In order to prevent SCSI signal loss, the provided external SCSI terminator
must be used at the end of the 68-pin SCSI cable. 50-pin SCSI cables may
also use terminators but usually use termination jumpers on the device it-
self. All termination jumpers must be removed when using the external SCSI
terminator.
4-6. Air Circulation System
Fan Replacement
The front and rear fans are both secured by plastic housings. The fan hous-
ings can be removed by pressing in the clip and sliding the housing upward.
IMPORTANT: When replac-
ing the fans, be sure that both fans
rotate in the same direction. Use the
manufacturer’s sticker on one side
of the fan as a reference. The air
should flow from the rear of the
chassis to the front of the chassis.
Press the clip with a screwdriver to
release.