Auto Scanning
The CS-1772 / CS-1774’s Auto Scan feature automatically cycles the KVM focus
through the computer ports at regular intervals. This allows you to monitor the
computer activity without having to take the trouble of switching from port to port
manually. See the table below for details.
Hotkey Action
[Scroll Lock] [Scroll Lock] [A] [Enter] Starts Auto Scan. The KVM focus cycles from port
to port at 5 second intervals.
[Scroll Lock] [Scroll Lock] [A] [n] [Enter] Starts Auto Scan. The KVM focus cycles from port
to port at n second intervals.
Note: 1. The n stands for the number of seconds that the CS-1772 / CS-1774 should
dwell on a port before moving on to the next. Replace the n with a number
between 1 and 99 when entering this hotkey combination.
2. Although the video focus switches from port to port, the keyboard, mouse,
audio and USB focus doesn’t switch. They stay at the port they were on
when Auto Scanning started.
3. While Auto Scan Mode is in effect, ordinary keyboard functions are
suspended - only Auto Scan Mode compliant keystrokes can be input. You
must exit Auto Scan Mode in order to regain normal control of the keyboard.
To exit Auto Scan Mode, press the Esc key, the Spacebar, or any Port Selection
switch.
2005-03-16
CS-1772 / CS-1774 User Manual
16