Operators Manual
ALS 230
Release 11/05 Page 27 Operation
y Error display:
If the display shows e.g. E__XX, the dispenser has recognised an error. A warning is shown
by W_XX. As soon as the error has been corrected, you may erase the message by
pressing the key ENTER and you will get back to the status the machine was in before the
error was indicated.
Note: Data entered in the standard menu are not stored, if the machine is switched off. If you
need to store data you have to use the extended menu. Please check if it is of help for you
using the product menu in your application.
Display Menu function Function data value
ON Labeller ready
OFF Label function suspend
POS label position on product Up to 999.9 mm
STOD Label stop position at the
dispensing edge
Depends on setting of DIST, Label
length and RAMP
VELO Dispensing speed 0.2 ... 30.0 m/min
STAD delay time before labelling starts 0,1 ... 999,9 ms
BLOW apply time 0,1 ... 999,9 ms
INIT Initialisation of label material
(CONT and LPIT are measured
according to label size)
Appears after E__0, E__1 and Power
on + FEED key depressed, or if the
values of CONT and LPIT are
changed
Dispenser active ___________________________________________________ ON
The dispenser is able to dispense labels.
Dispenser stopped_________________________________________________ OFF
The dispenser function is stopped. Single labels could be dispensed with the FEED key.
Material initialisation _______________________________________________ INIT
A new initialisation of material is necessary. Pressing the FEED key will start the initialisation.
Label position_____________________________________________________POS
The position of the label can be changed by the parameter POS while the machine is in
operation. The display is presented in 1/10 mm and means the distance between product
sensor and labelling position of the product. The display value 0500 would mean 50.0 mm. By