Avery ALS 230 Label Maker User Manual


 
Operators Manual
ALS 230
Release 11/05 Page 62 Connections and signals
8.3.2 OD Control sensor
Optional an OD control could be mounted to control the label roll. If the label material is nearly
empty the sensor gives an signal. A warning message and an output signal inform the personal
that in the next time the material has to be changed.
+24V
GND
14
black
green
white
red
brown
5
9
4
8
3
7
2
6
1
Signal-
GND
Signal+
Supply
white
grey
blue
25
11
27
CN33E3JK-R2M2
NPN sensor
5
9
4
8
3
7
2
6
1
Figure 17 NPN connection of optional ODC sensor
+24V
GND
14
black
green
white
red
25
11
27
CN33
brown
5
9
4
8
3
7
2
6
1
Signal-
GND
Signal+
Supply
white
grey
blue
S5-5-C8-30
PNP sensor
5
9
4
8
3
7
2
6
1
Figure 18 PNP connection of optional ODC sensor