2. Xenon bulb lamp replacement process
2.1 Removal of the lamp house
WARNING: This procedure may only be performed by qualied technical service personnel.
CAUTION: Lamp casing is very hot af ter operation. To avoid burns, let the projector cool down for at least 15
minutes before proceeding to the lamp unit replacement.
CAUTION: Due to its high internal pressure, the lamp may exp lode in either hot o r cold states if imp roperly
handled.
Necessary tools
7mmat screw drive r.
How to remove the lamp house of the projector ?
1. Switch off the projector.
2. Remove the lamp cover.
3. Release the three spring lock screws of the lamp house a s illustrated.
Image 2-1
4. Hold fast the lamp house by the handles and pull the lam p house o ut of the projector.
Caution: Beware of the weight of the lamp assembly. Take the necessary precautions to a void personal injury.
Image 2-2
5. Place the lamp house on a stable support.
8