2. Xenon bulb lamp replacement process
2.3 Installation of the xenon bulb lamp
WARNING: DO NOT PER MIT UN AUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE OF
XENON BULB LAMP HA NDLING OR SERVICE.
WARNING: This procedure may only be performed by qualied technical service personnel.
CAUTION: Xenon compact arc lamps are highly pressurized. W hen ignited, the normal op erating temperature
of the bulb increases the pressu re to a level at which the bulb ma y explode if not h andled in strict accordan ce
to the manufacturer ’s instructions. The bulb is stable at room temperature, but may still explode if dropped
or o therwise mishandled. Whe never the lamp house, containing a xenon bulb lamp, has to be dismantled or
whenever the protective con tainer or cloth has to be removed from the xenon bulb lamp, authorized protective
clothing MUST be worn!
WARNING: Always w ear face protection (full face shield with neck protector) when handling xen on bulb
lamps.
WARNING: Alwa ys wear protective clothing (welder’s jacket) w hen handling xenon bulb lamps.
WARNING: Always wear clean leather gloves w ith w rist pro tectors w hen handling xenon bulb lamps.
The DP-1200/DP-1500/DP-2000 projector is delivered without xenon bulb lamp installed. This procedure also
assumes that the lamp house is closed and that there is no xenon bulb lamp installed inside the lamp house.
Necessary tools
17 mm open ended wrench.
Torque wrench with 17 mm hexagon socket
Torque wrench with 5 mm Allen socket.
Necessary parts
Lamp cathode adapter.
Hexagon socket head screw M6 x 40.
Plane washer.
How to install the xenon bulb lamp into the lamp house?
1. Ensure that you wear protective clothing, a full face shield and protective gloves.
2. Remove the UV blocker and side cover of the lamp
house by releasing the r etaining thumbscrews as illustrated.
Note: In case of a lamp replacement, the UV blocker will be already remo ved.
R59770175 XENON BULB LAMP REPLACEMENT 24/09/2008