Service Mode
7-45975039 BARCOVISION 508 120198
Change baudrate
The communication speed between projector and computer has 8
possible speeds. The baud rate speed can be software set up.
Highlight 'Change Baudrate' by pushing the control disc up or down
and press ENTER to display the Baud rate menu.
The following baud rates are available :
- 9600
- 4800
- 2400
- 1200
- 600
- 300
- 150
- 110
The actual baud rate will be highlighted. To change the baud rate,
push the control disc up or down or to the left or to the right to select
the desired baud rate and press ENTER to accept this baud rate.
Select with or
then <ENTER>
<EXIT> to return.
PROJECTOR SET-UP
IDENTIFICATION
TOTAL RUN TIME
CHANGE PASSWORD
CHANGE PROJECTOR ADDRESS
CHANGE BAUDRATE
POWER UP MODE : operating
<ENTER> to accept
<EXIT> to return.
BAUDRATE
Select new
baudrate :
9600 4800
2400 1200
600 300
150 110
Select with arrow
keys ;
ENTER to accept the selected baud rate.
EXIT to return without changing the baud rate.
Power up mode
When pressing the power switch, the projector can start up in
'operating mode' or in 'stand-by mode'.
Operating mode : the projector start up and displays image .
Stand-by mode : the projector start up in stand-by and waits until the
stand-by button or a digit key is pressed.
To change the Power up mode, select Power Up mode by pushing
the control disc up or down and press ENTER to toggle between
'Operating' and 'Standby'.
Select with or
then <ENTER>
<EXIT> to return.
PROJECTOR SET-UP
IDENTIFICATION
TOTAL RUN TIME
CHANGE PASSWORD
CHANGE PROJECTOR ADDRESS
CHANGE BAUDRATE
POWER UP MODE : operating
ENTER to toggle between operating and standby.
EXIT to return to the Service menu.
Memory management
Highlight 'Memory management' by pushing the control disc up or
down and press ENTER to display the memory management menu.
Within the memory management menu, the following items can be
consultated or executed :
- copy a block
- delete a block
- delete all blocks
- all settings to midposition
- R & B convergence to mid
- Gr convergence mid (only if green convergence is available)
Select with or
then <ENTER>
<EXIT> to return.
SERVICE MODE
PROJECTOR SET-UP
MEMORY MANAGEMENT
COMMON SETTINGS
I2C DIAGNOSTICS
Select with or
then <ENTER>
<EXIT> to return.
MEMORY MANAGEMENT
COPY A BLOCK
DELETE A BLOCK
DELETE ALL BLOCKS
ALL SETTINGS TO MIDPOS
R & B CONVERGENCE MID
GR CONVERGENCE MID