Bay Technical Associates 303 Switch User Manual


 
Using the BayStack 303 and 304 Ethernet Switches
4-4 893-01010-A
If you are connecting a device to the BayStack switches that also implements
MDI-X ports (see Figure
4-2), use a crossover cable.
Figure 4-2. MDI-X to MDI-X cable connections
Installation-related Issues
Ethernet 10BASE-T networks tend to be fairly simple, but they can still have
problems that take time to resolve. The most common problems are associated
with the actual network wiring.
If you have problems with a newly established network (initial setup), the trouble
is most likely related to cabling or addressing. If the network has been operational
for an extended period and is now beginning to have problems, the trouble is
probably related to recent additions or changes.