Usage (continued)
You can switch directly to any port by giving the OmniView
SE the BANK and PORT
numbers. For instance, if you press [SCROLL LOCK] [SCROLL LOCK] [2] [2], the com-
puter on PORT 2 of the OmniView
SE set to BANK 2 will be selected. In the dia-
gram below, that is PC # 8. Hence, if you only have one OmniView
SE, the first key
(X) must be "0".
CONSOLE
Keyboard, mouse
and monitor
Bank 0 (Master)
Bank 1 (slave)
Bank 2 (slave)
Bank 3 (slave)
12
3456
78910
11 12
In AutoScan mode, the OmniView
SE remains on one port for a number of seconds,
before switching to the next. Set DIP switches 1 & 2 using the table below according
to a SCAN_TIME interval you prefer. If there are slave units present, the SCAN_TIME
setting is set on the MASTER unit only, and need not be set on the slave units.
AutoScan Mode
DIP SWITCH #
12
ON ON 7 seconds
ON OFF 15 seconds
OFF ON 30 seconds
OFF OFF 60 seconds
SCAN_TIME
NOTE: There is no mouse or keyboard control in this mode. This is necessary to
prevent errors. Otherwise, if the user is moving the mouse or using the keyboard
when the OmniView
SE switches to the next port, data flow is interrupted and will
cause erratic mouse movement and/or the wrong characters to show up when using
the keyboard.
To get out of AutoScan mode, press the [SPACEBAR].
Enable AutoScan mode