2.6 ETHERNET MANAGEMENT PORT
The LB510A-R2 offers a 10/100 Ethernet port for configuration and management via
Telnet sessions. Because the Ethernet port is configured as MDI, a crossover Ethernet
cable is required when connecting directly from a local PC or laptop. The Ethernet
interface default IP address is 192.168.200.1.
Through the Ethernet management port, the following variables can be configured or
m
onitored:
Pa
ssword: The password used to login to the console (1-10 characters).
Circ
uit ID: The circuit ID communicated to other units via EOC (1-64 charac-
ters). EOC (Embedded Operations Channel) is an out-of-band channel specified
i
n the G.991.2 standard for SHDSL.
Da
ta Rate: The DSL data rate is set by specifying the number of 64k timeslots.
A
nnex: Either G.991.2 Annex A or Annex B.
The following status information is available through the command line interface:
Co
nfiguration Mode: Whether the LB510A-R2 is configured by DIP switches or
software.
DSL Link State: In Progress, Success, Deactivated, or Idle.