Bosch Appliances D9210C Network Router User Manual


 
Access Control Interface Module Event Profile | en 13
Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 | 02 | 2011.10
This program item determines if Request to Enter [RTE] events are sent to the panel for
processing memory, printing, and remote reporting.
Yes A DOOR REQUEST TO ENTER event from this door controller is sent to the panel for
processing.
No A DOOR REQUEST TO ENTER event from this door controller is not sent to the panel for
processing.
This program item determines if Request to Exit [REX] events are sent to the panel for
processing memory, printing, and remote reporting.
Yes DOOR REQUEST TO EXIT event from this door controller is sent to the panel for
processing.
No A DOOR REQUEST TO EXIT event from this door controller is not sent to the panel for
processing.
D# Enter Request?
Default: No
Selections: Yes or No
NOTICE!
RTE events require D# Access Granted to be programmed [YES].
D# Exit Request?
Default: No
Selections: Yes or No
NOTICE!
REX events require D# Access Granted to be programmed [YES].