Bosch Appliances D9210C Network Router User Manual


 
Access Control Interface Module Door Profile | en 5
Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 | 02 | 2011.10
2 Door Profile
This programming category is used to:
Assign an area which also activates the interface module.
Assign a point to the door.
Program the door state to change when the arm state changes.
Allow for the strike relay to activate upon a fire alarm.
Enter the number of the door you are about to program.
Assign an area to the door controller. This entry allows the D9210C to be polled activating
communication to the panel. This also is the area a user will exit when initiating a Request to
Exit [REX].
1-8 The area assigned to the door controller to which the reader will allow access.
Blank Door controller will not function.
Enter the Command Center number [CC#] which determines the scope of the user ID’s
disarming rights. Areas will disarm on the basis of this Command Center’s scope and the
Authority Level of the user.
Door #
Default: 1
Selections 1-8
NOTICE!
The D9412 Family supports 8 doors; the D7412 Family supports 2 doors.
D# Entry Area #
Default: Blank
Selections: Blank, 1-8
NOTICE!
All SDI devices, regardless of area assigned, will report to Area 1, Account 1 by default upon
SDI failure. If an interface module becomes disconnected, SDI Fail ## and MISSING POINT ###
events will be created.
NOTICE!
9210 NOT READY will appear at this command center when you press the [ENTER] key if the
interface module is not programmed with a D# Entry Area.
D# CC# Scope
Default: Blank
Selections: Blank, 1-8