Bosch Appliances D9210C Network Router User Manual


 
Access Control Interface Module Strike Profile | en 9
Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 | 02 | 2011.10
3 Strike Profile
This programming category is used to create a specific door profile on:
Strike and shunt times.
Extending strike and shunt times if a door is left open.
Resetting the strike when the door opens.
Programming the interlock point.
Enter the door you are programming.
Enter the amount of time the relay output for the strike will activate to allow a user to open
the door. The strike will activate upon a valid token, Request to Enter [RTE], Request to Exit
[REX], and the Command Center [CYCLE DOOR?] function.
Blank Strike Time is not programmed for this door.
1-240 The strike will activate for the amount of time programmed.
Enter the amount of time that the door point will be shunted to allow a user to open the door
without causing the point to go into Trouble, Alarm or a faulted condition.
Blank TShunt Time is not programmed for this door.
1-240 The shunt will activate for the amount of time programmed.
Enter the amount of time that the buzzer output will activate to notify the user that the strike
has been activated and the door is ready to open. The buzzer will stop as soon as the door is
opened.
Door #
Default: 1
Selections 1-8
D# Strike Time
Default: 10
Selections: 1-240 seconds
D# Shunt Time
Default: 10
Selections: Blank, 1-240
D# Buzz Time
Default: 2
Selections: Blank, 1-240 seconds
NOTICE!
A separate buzzer is required. Many readers have an internal buzzer that is not affected by
Buzz Time.