Application Note
BlueBox Demo-Board for the digital sensors
SMB365 (acceleration) and SMD500 (pressure)
Bosch Sensortec
AN18002
Rev. 1.0
Page 31
© Bosch Sensortec GmbH reserves all ri
hts even in the event of industrial propert
ri
hts. We reserve all ri
hts of disposal such
cop
in
and passin
onto third parties.
7211RB11.
Settings Æ Measurements
According to customized settings (high signal resolution or low power consumption) it is
possible to choose different sample averaging numbers and update rates. E.g. increasing the
resolution leads to a decreased noise with increased power consumption and contrariwise. This
behavior can be edited by the following:
4.
Open Settings Æ Measurements
5.
The following message box appears
6.
Chose sampling average number and update rate according to the text
• sampling average number = Number of single values for avg. calculation
o edit by mouse scroll
• update rate = time for a new “send data command”
o Minimum update rate 0.5 s
• sample rate = update rate / sampling average number
o Minimum sampling rate 0.1 s
o Maximum 2 values per second (2 Hz) possible