Bosch Appliances SMB365 Computer Hardware User Manual


 
Application Note
BlueBox Demo-Board for the digital sensors
SMB365 (acceleration) and SMD500 (pressure)
Bosch Sensortec
AN18002
Rev. 1.0
Page 33
© Bosch Sensortec GmbH reserves all ri
g
hts even in the event of industrial propert
y
ri
g
hts. We reserve all ri
g
hts of disposal such
cop
y
in
g
and passin
g
onto third parties.
7211RB11.
4.3 The BlueBox Accelerometer Window
The following figure gives an overview of the BlueBox Accelerometer Window
20. Sensor Mode selection
Normal Power for full performance mode (10bit resolution)
Low Power for interrupt mode (7bit resolution)
Standby for energy saving mode (0bit resolution)
21. Acceleration range selection
± 2g for low g applications
± 10g for high g applications
22. Interrupt mode selection
global interrupt conditions (same for all axes)
independent interrupt conditions (individual for each axis)
20
21
22
24
25
23
26
28
27
29
30
5