Application Note
BlueBox Demo-Board for the digital sensors
SMB365 (acceleration) and SMD500 (pressure)
Bosch Sensortec
AN18002
Rev. 1.0
Page 42
© Bosch Sensortec GmbH reserves all ri
hts even in the event of industrial propert
ri
hts. We reserve all ri
hts of disposal such
cop
in
and passin
onto third parties.
7211RB11.
4.4 Sensor Evaluation and Direct Data Export
Using the BST Sensor Desktop software in combination with the BlueBox demo board, it is
possible to perform a minor sensor evaluation. This includes both the SMD500 pressure and the
SMB365 acceleration sensor simultaneously. For basic evaluation purposes, the software
features a so-called online Direct Data Export in *.txt format via USB or wireless via Bluetooth.
The Direct Data Export is unlimited in time. While exporting the Data, for each tab activated
(Cockpit, Altimeter or Accelerometer) a corresponding header is automatically added to the *.txt
file. This means that only the active tab corresponding data is recorded.
Note: To sample either pressure or acceleration specific signals please use corresponding tab
for increased sampling speed.
How to perform a Direct Data Export:
• Open menu “Export Data” from the Sensor Desktop menu bar.
• Check “Activated” box
• Browse and/or create storage folder
• Choose appropriate filename and confirm with “OK”