Application Note
BlueBox Demo-Board for the digital sensors
SMB365 (acceleration) and SMD500 (pressure)
Bosch Sensortec
AN18002
Rev. 1.0
Page 42
© Bosch Sensortec GmbH reserves all ri
g
hts even in the event of industrial propert
y
ri
g
hts. We reserve all ri
g
hts of disposal such
cop
y
in
g
and passin
g
onto third parties.
7211RB11.
4.4 Sensor Evaluation and Direct Data Export
Using the BST Sensor Desktop software in combination with the BlueBox demo board, it is
possible to perform a minor sensor evaluation. This includes both the SMD500 pressure and the
SMB365 acceleration sensor simultaneously. For basic evaluation purposes, the software
features a so-called online Direct Data Export in *.txt format via USB or wireless via Bluetooth.
The Direct Data Export is unlimited in time. While exporting the Data, for each tab activated
(Cockpit, Altimeter or Accelerometer) a corresponding header is automatically added to the *.txt
file. This means that only the active tab corresponding data is recorded.
Note: To sample either pressure or acceleration specific signals please use corresponding tab
for increased sampling speed.
How to perform a Direct Data Export:
• Open menu “Export Data” from the Sensor Desktop menu bar.
• Check “Activated” box
• Browse and/or create storage folder
• Choose appropriate filename and confirm with “OK”