Brocade Communications Systems 6910 Switch User Manual


 
Brocade 6910 Ethernet Access Switch MIB Reference 21
53-1002582-01
Chapter
4Physical Properties of a Device
Common objects
This chapter presents the global objects for the general management of a device’s physical
properties, such as the current status of the power supply and fan.
Refer to the configuration guide for details on power supplies, fans, and other features discussed in
this chapter.
Power supply
The following object applies to all devices. Refer to the chapter, “Physical Properties of a Device” on
page 21, for information on power supply traps.
Boards
Chassis table
The snChasUnitTable manages the temperature for the devices.
Name, Identifier, and Syntax Access Description
snChasMainBrdDescription
brcdIp.1.1.1.1.5
Syntax: DisplayString
Read only The main board description string. This object can have up to 128
characters.
snChasMainPortTotal
brcdIp.1.1.1.1.6
Syntax: Integer
Read only Shows the total number of ports on the main board.
Valid values: 1 – 24
Name, Identifier, and Syntax Access Description
snChasUnitTable
brcdIp.1.1.1.4.1
N/A A table of chassis information for each unit. Only activechassis
appears in a table row.
snChasUnitEntry
brcdIp.1.1.1.4.1.1
N/A A row in the chassis table.
snChasUnitIndex
brcdIp.1.1.1.4.1.1.1
Syntax: Integer32
Read only The index to the table
snChasUnitSerNum
brcdIp.1.1.1.4.1.1.2
Syntax: DisplayString
Read only The serial number of the unit. If the serial number is unknown
or unavailable, then the value should be a zero length string