General security objects
The following objects are used to manage general security functions.
Name, Identifier, and Syntax Access Description
snAgWebMgmtServerTcpPort
brcdIp.1.1.2.1.64
Syntax: Integer
Read-write This object allows you to specify which TCP port will be used for
the Web management interface.
Enter a number from 1 – 65535.
Name, Identifier, and Syntax Access Description
snAgGblTelnetTimeout
brcdIp.1.1.2.1.37
Syntax: Integer
Read-write Shows how many minutes a Telnet session can remain idle
before it times out. The value of this object can be up to 1093
minutes.
snAgGblEnableWebMgmt
brcdIp.1.1.2.1.38
Syntax: Integer
Read-write Enables or disables access to the device from the Web
management interface:
disable(0)
enable(1)
Default: enable(1)
snAgGblEnableTelnetServer
brcdIp.1.1.2.1.45
Syntax: Integer
Read-write Enables or disables the Telnet server in a device:
Disable(0)
Enable(1)
Default: enable(1)
snAgGblTelnetLoginTimeout
brcdIp.1.1.2.1.60
Syntax: Integer
Read-write
Indicates how many minutes you have to log in before Telnet is
disconnected.
Valid values: 1 – 5 minutes.