Brother HL-7050 Series Printer User Manual


 
CONTROL PANEL 3 - 32
HL7050_US_UG_FM5.5
INTERFACE
Display Shows Description
SELECT =AUTO/PARALLEL/RS-232C/USB/NETWORK
AUTO IF TIME = 1:99 (sec)
You need to set the time-out period for the auto interface
selection.
INPUT BUFFER = Level1:15
Increase or
decrease the input
buffer capacity.
RESTART PRINTER?
PARALLEL When using the parallel interface
Sub-setting Menu Description
HIGH SPEED =ON/OFF
Turns high-speed parallel
communications on or off.
BI-DIR =ON/OFF
Turns bi-directional parallel
communications on or off.
RS-232C When using the serial interface
Sub-setting Menu Description
FAX MODE =OFF/ON RESTART PRINTER?
BAUDRATE
*1
Data transfer speed can be set to
150/300/600/1200/2400/4800/9600/
19200/38400/57600/115200 baud.
CODETYPE
*1
=8 BITS/7 BITS
The data length can be set to 7 or 8
bits.
PARITY
*1
=NONE/ODD/EVEN
The data error check can be set to
NONE, ODD or EVEN.
STOP BIT
*1
=1 BITS/2 BITS
The data separator can be set to 1 or
2 stop bits.
XON/XOFF
*1
=ON/OFF
Handshake protocol can be set to on
or off.