Cabletron Systems SEHI100TX-22 Switch User Manual


 
The SNMP Tools Screen
SEHI100TX User’s Guide 7-21
Enter an “=” and the OID suffix (e.g., if =4.1.3 is entered, then the
OID=4.1.3). This allows the user to not use the prepend.
Press F9 to recall an OID already entered. The user can then use
the keyboard to modify the recalled OID as necessary.
3. Press ENTER. If there is no instance of that OID, the return code
specifies “MIB_NO_INSTANCE”, otherwise, information about the
data type, length, and value of that OID appears.
7.8.2 Getting the Next OID
Use the following steps to GET the next OID:
1. Highlight GETNEXT with the arrow keys, then press ENTER or F8.
“<GETNEXT> OID (=|F9)” appears.
2. Enter the desired OID, or OID extension. (Press F9 to recall the last
OID request. The recalled OID may then be modified as necessary.)
3. Press ENTER. If there is no instance of that OID, the return code
specifies “MIB_NO_INSTANCE”, otherwise, information about the
data type, length, and value of that OID appears.
7.8.3 Setting an OID
Use the following steps to SET an OID:
1. Highlight SET by using the arrow keys, then press ENTER or F7.
“<SET> OID (=|F9)” appears.
2. Enter the OID, minus the OID prepend. If the OID was previously
entered, pressing F9 recalls that entry. The arrow keys may be used to
modify the recalled OID if necessary.