Cabletron Systems T1 Switch User Manual


 
Chapter 2: Setup and Installation
2-2 WPIM-T1/DDS User’s Guide
2.1.2 Pre-Installation
To prepare the host platform for the WPIM-T1/DDS, proceed as follows:
1. Turn off and disconnect the host platform from the power source.
2. Mark all network cables attached to the host platform for ease of
re-installation.
3. Disconnect all network cables attached to the host platform.
4. Refer to detailed instructions contained in the host platform’s user
guide to remove the chassis cover. This procedure must be completed
before installing the WPIM-T1/DDS.
2.1.3 Installing the WPIM-T1/DDS
To install the WPIM-T1/DDS into the device, refer to Figure 2-1 and
complete the following steps:
1. Remove the blank faceplate from the appropriate WAN slot by
removing the three WPIM screws that secure it to the standoffs.
2. Orient the WPIM-T1/DDS as shown in Figure 2-1.
3. Carefully insert the WPIM-T1/DDS connector into the WPIM
connector pins on the device.
4. Press down firmly on the WPIM-T1/DDS until the pins slide all the
way into the connector. Ensure that the WPIM-T1/DDS seats flush on
the standoffs.
5. Secure the WPIM-T1/DDS to the three standoffs with the WPIM
screws.
!
CAUTION
When removing an existing WPIM, make sure to pull the
module straight up to avoid damaging the connector.