Cabletron Systems WPIM-RT1 Network Card User Manual


 
Frame Relay Configuration
WPIM-RT1 User’s Guide 3-19
3. Insert the interface number (refer to NOTE below) into the timeslot
being used. Type the number, press ENTER, then exit this field by
using the arrow keys. The cursor automatically moves to the T1 Line
Coding field.
The next four steps are based on information supplied by the service
provider. Consult the service provider for the correct settings.
4. Use the arrow keys to highlight T1 Line Coding. Press the SPACE bar
to select B8ZS or AMI, then press ENTER.
5. Use the arrow keys to highlight T1 Frame Type. Press the SPACE bar
to select ESF or D4, then press ENTER.
6. Use the arrow keys to highlight T1 Tx Clock Source. Press the
SPACE bar to select Local (no clock source provided by telephone
company) or Loop (clock source provided by telephone company),
then press ENTER.
7. Use the arrow keys to highlight T1 Line Buildout (LBO). Press the
SPACE bar to select to 0 dB unless the service provider recommends
another setting, then press ENTER.
8. Use the arrow keys to highlight the SAVE command, then press
ENTER. The message “SAVE DONE!” displays and Local
Management saves the changes to memory. “REBOOT IN
PROGRESS......” displays and the host platform reboots. Re-entry to
management is necessary for any further configuration.
9. Proceed to Section 3.5.2 to continue the configuration.
NOTE
The value assigned to the timeslots is the interface being used
for WAN communication. Only one interface can be assigned to
the timeslot when running Frame Relay.