Cisco Systems 7401ASR Network Router User Manual


 
3-7
Cisco 7401ASR Installation and Configuration Guide
OL-5419-01 B0
Chapter 3 Starting and Configuring
Functional Overview
Temperature readings:
chassis inlet measured at 29C/84F
chassis outlet measured at 26C/78F
Voltage readings:
+1.8 V (PXF) measured at +1.79 V
+1.8 V (CPU) measured at +1.77 V
+2.50 V measured at +2.47 V
+3.30 V measured at +3.28 V
+5.00 V measured at +4.98 V
+5.20 V measured at +5.18 V
+12.25 V measured at +12.21 V
-12.00 V measured at -12.15 V
Fans:
Fan 1 is believed to be working
Fan 2 is believed to be working
Fan 3 is believed to be working
Fan 4 is believed to be working
Fan 5 is believed to be working
With a single 24V DC power supply installed:
Router# show environment all
Power Supplies:
Power supply 1 is Internal 24VDC Power Supply. Unit is on.
Power supply 2 is unmeasured.
Temperature readings:
chassis inlet measured at 35C/95F
chassis outlet measured at 29C/84F
Voltage readings:
+1.8 V (PXF) measured at +1.79 V
+1.8 V (CPU) measured at +1.77 V
+2.50 V measured at +2.47 V
+3.30 V measured at +3.28 V
+5.00 V measured at +4.98 V
+5.20 V measured at +5.18 V
+12.25 V measured at +12.36 V
-12.00 V measured at -12.15 V
Fans:
Fan 1 is believed to be working
Fan 2 is believed to be working
Fan 3 is believed to be working
Fan 4 is believed to be working
Fan 5 is believed to be working
With a single 48V DC power supply installed:
Router# show environment all
Power Supplies:
Power supply 1 is Internal 48VDC Power Supply. Unit is on.
Power supply 2 is empty.
Temperature readings:
chassis inlet measured at 34C/93F
chassis outlet measured at 28C/82F
Voltage readings:
+1.8 V (PXF) measured at +1.79 V
+1.8 V (CPU) measured at +1.77 V