2-11
Cisco 806 Router and SOHO 71 Router Hardware Installation Guide
78-10432-04
Chapter 2 Installation
Installing Your Router
Figure 2-5 Connecting a Terminal or PC
Note If the factory default configuration does not allow you to connect to the
Internet, it is recommended that you configure your router using the
Cisco Router Web Setup (CRWS) software. The CRWS software is installed
on your router at the factory. See the “What to Do If You Cannot Connect to a
Website” section on page 2-17 for instructions on starting the CRWS software.
Connecting the AC Adapter
To connect the AC adapter, follow the steps in Figure 2-6. (Figure 2-6 shows a
Cisco 806 router, but the process is the same for a SOHO 71 router.)
Warning
The device is designed to work with TN power systems.
Warning
This product relies on the building’s installation for short-circuit (overcurrent)
protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S.
(240 VAC, 16A international) is used on the phase conductors (all
current-carrying conductors).
ETHERNET
TO HUB
TO PC
+5 VDC
4
32
1
10BASET
Model Cisco 806
COMPUTERS (E0)
ETHERNET 10BASET
INTERNET (E1)
CONSOLE
2. Connect DB-9 connector
to terminal or PC.
1. Connect RJ-45 connector
on light blue cable to
CONSOLE port.
51821