Cisco Systems TD 92322GB Server User Manual


 
TD 92322GB
2007-06-26/ Ver. D
Installation and Operation Manual
Integrated Message Server, IMS/IP-WiFi
12
6.1 Nomenclature
6.2 Technical Specification
6.3 Parameter Setup
When the IMS/IP is delivered, the 900 Interface is configured to send all Input Activity
information to the Basic Alarm Manager. The interface is configured to send all Alarms
and User Data from the handset to the Basic Alarm Manager. These settings can be
changed when the IMS/IP parameters are restored from file, i.e. check that the settings are
as described below.
Configuration of Input Activity
1
1 Open the IMS/IP administration pages and click “Message Distribution” for the 900
Interface.
2 Click “Input Activity”, see figure 5.
Figure 5. Setting up the Message Distribution list for the 900 Interface to send
information to the Basic Alarm Manager.
Input An input on the IMS/IP or an input on an Alarm Module connected to the A-
bus.
Output An output on the IMS/IP or an output on an Output Module connected to the
A-bus.
Trigger A set of conditions that detects whether an input has been activated, or an
alarm or data has been sent from a VoWiFi handset.
Action Sending a message to a Unite Call ID for example Pocket Unit address included
in the UNS or activating an output.
Event A set of triggers that starts one or several actions.
Max. No. of triggers: 250
Max. No. of triggers / event: 10
Max. No. of defined inputs: 250
Max. No. of actions: 250
Max. No. of actions / event: 10
Max. No of defined outputs: 250
Alarm Module requirements: Software version 4.00
1
1.From this version the Alarm Module can be configured to send Input Activity information both when the input is
opened and closed. Previous versions have no support for this.