ESC @
[Function] Initializing the printer
[Code] <1B> H <40> H
[Outline] Clears data stored in the print buffer and brings various settings to the initial
state (Default state).
[Caution]
·
Data inside the internal input buffer are not cleared.
·
Dip switches setting are red once again.
[Sample Program] [Print Results]
LPRINT CHR$ (&H1B) ; " ! " ; CHR$ (&H30) ;
LPRINT CHR$ (&H1B) ; "V" ; CHR$ (1) ;
LPRINT "AAA" ; CHR$ (&HA) ;
LPRINT CHR$ (&H1B) ; "@" ;
LPRINT "AAA" ; CHR$ (&HA) ;
ESC D [ n ] k NUL
[Function] Setting horizontal tab position
[Code] <1B> H <44> H [<n>] k <00> H
[Range] 1
£
n
£
255
0
£
k
£
32
[Outline] Specifying a horizontal tab position.
·
"n" indicates the no. of columns from the beginning to the horizontal tab
position. At this time, n= set position
-
1 is to be specified. For example, to set
the position at 9th column, n=8 is to be specified.
·
k denotes the number of horizontal tab positions you want to set.
·
The tab position is set at position where it is "character width x n" from the line
beginning. The character width, at this time, includes the rightward space
amount. In double wide characters, it is made double of the ordinary case.
·
Tab positions can be specified are maximum 32. Specifying exceeding this is
ignored.
·
<n> k, which denotes a setting position, is input in the increasing order and
ends at <00> H.
·
ESC D NUL clears all the set tab positions. Following clearing, horizontal
tab command is ignored.
[Caution] When the data, <n> k, is equal to or smaller than its preceding data, <n> k-1, it is
assumed that tab setting is finished. If this is the case, the next data onward
will be processed as normal data.
When the data, <n> k, exceeds a 1-line print area, set the horizontal tab position,
assuming "Set digit position = Maximum print digits + 1." The horizontal tab
position does not change even if the character width is altered after setting the
horizontal tab position.
[Default]
·
Initial value is specified for each eight characters(9th.17th.25th.33rd columns)
of Font A.
[See Also] HT
[Sample Program] [Print Results]
See Sample Program and Print Results for HT on Page 46.
Each setting has
been initialized by
the reset command.