—45—
MSW6-1 Act. For Driver Invalid Valid
MSW6-2 Character Space
Invalid Valid
MSW6-3 Reserved
Fixed
MSW6-4 Reserved
Fixed
MSW6-5 Reserved
Fixed
MSW6-6 Reserved
Fixed
MSW6-7 Reserved
Fixed
MSW6-8 Reserved
Fixed
N. switch Funzione
Impostazione
iniziale
Valore impostato
*2 MSW7-1 Baud Rate 9600 bps 1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps,
38400 bps, 57600 bps, 115200 bps
*2 MSW7-2 Data Length 8bits 7bits, 8bits
*2 MSW7-3 Stop Bit 1bit 1bit, 2bits
*2 MSW7-4 Parity NONE NONE, EVEN, ODD
*2 MSW7-5 Flow Control DTR/DSR DTR/DSR, XON/XOFF
*2 MSW7-6 DMA Control Valid Valid, Invalid
*2 MSW7-7 VCom Protocol PC Setting PC Setting, DTR/DSR, XON/XOFF
MSW8-1 Print Width
576dots
(Tipo da 3 pollici)
384dots
(Tipo da 2 pollici)
640dots, 576dots, 512dots, 436dots, 432dots,
420dots, 384dots, 360dots, 390dots, 546dots,
390dots, 546dots
MSW8-2 Paper Type
1 Color Normal 1 Color Normal, 2 Color Normal
MSW9-1 Code Page
PC 437 PC 437, Katakana, PC 850,858, PC 860, PC 863,
PC 865, PC 852, PC 866, PC 857, WPC1252,
Space page, PC 864, Thai Code 18
MSW9-2 Int’Char Set
USA USA, France, Germany, England, Denmark, Sweden,
Italy, Spain, Japan, Norway, Denmark 2, Spain 2,
Latin America, Korea, Croatia, China
MSW9-3 Kanji
OFF ON, OFF
MSW9-4 JIS/Shift JIS
JIS JIS, Shift JIS
MSW9-6 LCD Language
English English, Français, Deutsch, Italiano, Español,
Japanese
MSW9-7 LCD Ext Char
Valid Invalid, Valid
MSW9-8 LCD Auto Off
Never Never, 30seconds, 5minutes
MSW10-1 Print Density
100 % 70 %, 75 %, 80 %, 85 %, 90 %, 95 %, 100 %, 105 %,
110 %, 115 %, 120 %, 125 %, 130 %, 135 %, 140 %
MSW10-2 Print Speed
Level 9 Level 1, Level 2, Level 3, Level 4, Level 5, Level 6,
Level 7, Level 8, Level 9
MSW10-3 ACK Timing
Before Busy Before Busy, Same Period, After Busy
MSW10-4 Reserved
MSW10-5 Reserved
MSW10-6 Buzzer Sound
Tone 2 Tone 1, Tone 2, Tone 3, Tone 4
MSW10-7 Key Lock
Invalid Invalid, Valid
MSW10-8 Reserved
N. switch Funzione OFF ON