Citizen Systems 291 Printer User Manual


 
CBM-290/291 User’s Manual
14
CITIZEN
4. Dip switch setting
Dip switch locates on the rear side of main body. Make sure that power is turned OFF before changing Dip
switch settings. Change during power is ON can not be effective.
DIP SWITCH
ON OFF FACTORY SETTING
DS1-1 AUTO CUTTER EQUIPPED NONE OFF = CBM-290
ON = CBM-291
2 CR SELECTION LF ENABLE LF DISABLE OFF
3 PRINT DENSITY STANDARD DARKER OFF
4 DTR-DSR/XON-XOFF XON-XOFF DTR/DSR OFF
5 INTERFACE OFF
6 " SEE BELOW OFF
7" OFF
8
"OFF
DS1-
8 7 6 5 INPUT METHOD PARITY BAUD RATE
OFF OFF OFF OFF PARALLEL INPUT -- --
OFF OFF OFF ON SERIAL INPUT NONE 1200 bps
OFF OFF ON OFF " " 2400 bps
OFF OFF ON ON " " 4800 bps
OFF ON OFF OFF " " 9600 bps
OFF ON OFF ON " " 19200 bps
OFF ON ON OFF " ODD 1200 bps
OFF ON ON ON " " 2400 bps
ON OFF OFF OFF " " 4800 bps
ON OFF OFF ON " " 9600 bps
ON OFF ON OFF " " 19200 bps
ON OFF ON ON " EVEN 1200 bps
ON ON OFF OFF " " 2400 bps
ON ON OFF ON " " 4800 bps
ON ON ON OFF " " 9600 bps
ON ON ON ON " " 19200 bps
Remarks : For CBM-290, It make Error when ON is selected for DS1-1.
DS1-4 is ignored when parallel input is specified.
Some specifications has been selected in factory setting by jumper as follows.
Jumper International model
J1 Short
J2 Short
J3 Short
J4 Short
J5 Short
J6 Short
J7 Short
J8 Open
International model
International character : U.S.A.
Auto-loading : Enabled
Input Buffer : 4 K bytes
Serial communication bit length : 8 bit