ConnectPRO SL2116A Computer Monitor User Manual


 
In the Settings window navigate to the Time line and press Enter. The Time settings window
appears see Figure 12.
Figure 12 Time settings window
Scan (SCN) - Label (LBL) - Time out (T/O)
SCN SCN column, change the scan period.
LBL - In the LBL column, change the display period of the OSD label showing which computer is
currently accessed.
T/O - When password protection is activated you can automatically disable the Management
keyboard, mouse and screen after a preset time of non-use. Set this Timeout period in the T/O
column.
To set the above periods:
1. On the desired line press Tab to jump to the desired column.
2. Place the cursor over one of the 3 digits and type a new number. Enter a leading zero where
necessary. For example, type 040 for 40 seconds.
Typing 999 in the LBL column displays the label continuously. Typing 000 the label will not
appear.
Typing 999 in the T/O column disables the Timeout function. Typing 000 the Timeout
function works immediately.
Typing 999 in the SCNn displays the screen for 999 seconds. Typing 000 the computer screen
is skipped.
25. Users
In the Settings window navigate to the Users line and press Enter. The Users settings window
appears see Figure 13.