Dell 1900 Personal Computer User Manual


 
About Your System 17
E1211 ROMB Batt RAID battery is either missing,
bad, or unable to recharge due to
thermal issues.
Reseat the RAID battery. See
"Replacing the SAS RAID
Controller Daughter Card
Battery" on page 92, and
"Troubleshooting System Cooling
Problems" on page 109.
E12
nn XX
PwrGd Specified voltage regulator has
failed.
See "Getting Help" on page 131.
E1229 CPU # VCORE Processor # VCORE voltage
regulator has failed.
See "Getting Help" on page 131.
E122B 0.9V Over
Voltage
0.9 V regulator voltage has
exceeded the allowable voltage
range
See "Getting Help" on page 131.
E122C CPU Power Fault A voltage regulator failure was
detected when the processor
regulator(s) was enabled
See "Getting Help" on page 131.
E1310 RPM Fan ## RPM of specified cooling fan is
out of acceptable operating range.
See "Troubleshooting System
Cooling Problems" on page 109.
E1410 CPU # IERR Specified microprocessor is
reporting a system error.
See your system’s Information
Update Tech Sheet located on
support.dell.com for the most
current system information. If the
problem persists, see "Getting
Help" on page 131.
Table 1-4. LCD Status Messages (continued)
Code Text Causes Corrective Actions