Dell 1900 Personal Computer User Manual


 
About Your System 21
E201F DRAC Config Dell remote access controller
(DRAC) configuration failure.
Check screen for specific error
messages.
Ensure that DRAC cables and
connectors are properly seated. If
problem persists, see your DRAC
documentation.
E2020 CPU Config CPU configuration failure. Check screen for specific error
messages.
E2021 Memory
Population
Incorrect memory configuration.
Memory population order
incorrect.
Check screen for specific error
messages. See "Troubleshooting
System Memory" on page 110.
E2022 POST Fail General failure after video. Check screen for specific error
messages.
E2110 MBE DIMM ## & ## One of the DIMMs in the set
implicated by "## & ##" has
had a memory multi-bit error
(MBE).
See "Troubleshooting System
Memory" on page 110.
E2111 SBE Log Disable
DIMM ##
The system BIOS has disabled
memory single-bit error (SBE)
logging, and will not resume
logging further SBEs until the
system is rebooted. "##"
represents the DIMM implicated
by the BIOS.
See "Troubleshooting System
Memory" on page 110.
E2112 Mem Spare DIMM
##
The system BIOS has spared the
memory because it has
determined that the memory had
too many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS.
See "Troubleshooting System
Memory" on page 110.
E2113 Mem Mirror DIMM
## & ##
They system BIOS has disabled
memory mirroring because it has
determined that one half of the
mirror has had too many errors.
"## & ##" represents the
DIMM pair implicated by the
BIOS.
See "Troubleshooting System
Memory" on page 110.
Table 1-4. LCD Status Messages (continued)
Code Text Causes Corrective Actions