Dell 1900 Personal Computer User Manual


 
20 About Your System
E1913 CPU & Firmware
Mismatch
The BMC firmware does not
support the CPU.
Update to the latest BMC
firmware. See the BMC User’s
Guide for more information on
setup and use of BMC.
E2010 No Memory No memory is installed in the
system.
Install memory. See "Memory" on
page 80.
E2011 Mem Config Err Memory detected, but is not
configurable. Error detected
during memory configuration.
See "Troubleshooting System
Memory" on page 110.
E2012 Unusable Memory Memory is configured, but not
usable. Memory subsystem
failure.
See "Troubleshooting System
Memory" on page 110.
E2013 Shadow BIOS Fail The system BIOS failed to copy
its flash image into memory.
See "Troubleshooting System
Memory" on page 110.
E2014 CMOS Fail CMOS failure. CMOS RAM not
functioning properly.
See "Getting Help" on page 131.
E2015 DMA Controller DMA controller failure. See "Getting Help" on page 131.
E2016 Int Controller Interrupt controller failure. See "Getting Help" on page 131.
E2017 Timer Fail Timer refresh failure. See "Getting Help" on page 131.
E2018 Prog Timer Programmable interval timer
error.
See "Getting Help" on page 131.
E2019 Parity Error Parity error. See "Getting Help" on page 131.
E201A SIO Err SIO failure. See "Getting Help" on page 131.
E201B Kybd Controller Keyboard controller failure. See "Getting Help" on page 131.
E201C SMI Init System management interrupt
(SMI) initialization failure.
See "Getting Help" on page 131.
E201D Shutdown Test BIOS shutdown test failure. See "Getting Help" on page 131.
E201E POST Mem Test BIOS POST memory test failure. See "Troubleshooting System
Memory" on page 110. If problem
persists, see "Getting Help" on
page 131.
Table 1-4. LCD Status Messages (continued)
Code Text Causes Corrective Actions