Dell 2950 Server User Manual


 
Information Update 13
PCIe Training
Error: Slot n
Faulty or improperly
installed PCIe card in
the specified slot.
Reseat the PCIe card in the
specified slot number. See
“Expansion Cards” in the
Hardware Owner’s Manual.
If the problem persists, see
“Getting Help” in the
Hardware Owner’s Manual.
Remote Access
Controller cable
error or incorrect
card in the RAC
slot.
RAC cables not connected,
or RAC card installed in
wrong expansion slot.
Check that the RAC cables
are connected, and that the
RAC card is installed in the
correct expansion slot. See
“Installing a RAC Card” in
the Hardware Owner’s
Manual.
NOTE: All TPM information messages appear after the BMC option ROM has been
loaded during POST.
TPM configuration
operation honored.
System now resets. Information only.
TPM Failure A Trusted Platform Module
(TPM) function has failed.
See “Getting Help” in the
Hardware Owner’s Manual.
TPM operation is
pending. Press I to
Ignore or M to
Modify to allow
this change and
reset the system.
WARNING: Modifying
could prevent
security.
Configuration change has
been requested.
Press I to continue system
boot. Press M to modify
the TPM setting and
restart.
Warning: Following
faulty DIMMs are
disabled:
DIMM n
1
n
2
Total memory size
is reduced.
Faulty or improperly
seated memory module(s).
DIMMs are disabled in
pairs, as indicated by the n
1
and n
2
. Check both
DIMMs for a possible fault.
See “Troubleshooting
System Memory” in the
Hardware Owner’s Manual.
Table 1-1. System Messages (continued)
Message Causes Corrective Actions