Dell 2950 Server User Manual


 
18 Information Update
E1914 DRAC5 Conn2
Cbl
DRAC 5 cable is missing
or disconnected.
Reconnect the cable.
See “Installing a RAC
Card” in the Hardware
Owner’s Manual.
E1B01 USB#
Overcurrent
Device plugged in the
specified USB port caused
an overcurrent condition.
Reseat the device cable.
If the problem persists,
replace or remove the
device.
E2110 MBE
DIMM # & #
One of the two indicated
DIMMs has had a
memory multi-bit error
(MBE).
See “Troubleshooting
System Memory” in the
Hardware Owner’s
Manual.
E2111 SBE Log
Disable
DIMM #
The system BIOS has
disabled memory single-
bit error (SBE) logging,
and does not resume
logging further SBEs until
the system is restarted.
“#” represents the DIMM
implicated by the BIOS.
See “Troubleshooting
System Memory”
in the Hardware
Owner’s Manual.
E2112 Mem Spare
DIMM #
The system BIOS has
spared the memory
because it has determined
that the memory had
too many errors. “# & #”
represents the DIMM pair
implicated by the BIOS.
See “Troubleshooting
System Memory”
in the Hardware
Owner’s Manual.
I1915 Video Off
(LCD lights with
a blue or amber
background.)
The video has been
turned off by the RAC
remote user.
Information only.
I1916 Video Off
in ##
(LCD lights with
a blue or amber
background.)
The video was turned off
in xx seconds by the RAC
remote user.
Information only.
Table 1-2. LCD Status Messages (continued)
Code Text Causes Corrective Actions