Dell 2950 Server User Manual


 
16 Information Update
E1211 ROMB Batt RAID battery is either
missing, bad, or unable
to recharge due to
thermal issues.
Reseat the RAID
battery connector. See
the “RAID Battery” and
see “Troubleshooting
System Cooling
Problems” in the
Hardware Owner’s
Manual.
E1625 PS AC Current Power source is out
of acceptable range.
Check the AC power
source.
E1711 PCI PERR B##
D## F##
The system BIOS has
reported a PCI parity
error on a component
that resides in PCI
configuration space
at bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see “Troubleshooting an
Expansion Card” in the
Hardware Owner’s
Manual.
PCI PERR
Slot #
The system BIOS has
reported a PCI parity
error on a component
that resides in the
specified PCIe slot.
Reinstall the expansion-
card riser. See
“Expansion Card
Risers” in the Hardware
Owner’s Manual.
If the problem persists,
the riser card or system
board is faulty.
See “Getting Help”
in the Hardware
Owner’s Manual.
Table 1-2. LCD Status Messages (continued)
Code Text Causes Corrective Actions